Tel: +386 1 518-17-24
Fax: +386 1 256-73-53
GSM: +386 51 301 955

APST

APST-silicone-tubing_200px

Žao nam je, ne postoji prijevod na raspolaganju za ovaj proizvod još američki engleski. For the sake of viewer convenience, the content is shown below in the alternative language. You may click the link to switch the active language.

APST: Unreinforced Silicone Tubing

Low volatile grade, platinum-cured silicone tubing is clean room produced for critical pharmaceutical, biomedical, cosmetic, and food applications. APST platinum cured tubing has undergone extensive physical, chemical, and biological testing, and meets USP Class VI, FDA CFR 177.2600, ISO 10993, NSF 51, European Pharmacopoeia 3.1.9, and 3-A standards.

APST Unreinforced Platinum Cured Silicone Tubing is not intended for implantation, continuous steam applications, or elevated pressure levels.

KEY FEATURES

  • Hardness value of 50 Shore A
  • Extremely flexible
  • General temperature range: -100° F (-73.3° C) to 400° F (204.4° C)
  • Sterilizable by autoclave or gamma radiation
  • Available with validated sterility assurance of 10-6 via gamma irradiation per ISO 11137 method VDmax 25
  • Low volatile grade suitable for pharmaceutical and biomedical applications
  • Listed by the National Sanitation Foundation for food equipment materials (NSF-51)
  • Certified free of animal-derived ingredients
  • Resists temperature extremes, compression set, chemical attack, ozone, radiation, moisture, and environmental exposure
  • Imparts no taste or odor to critical streams
  • Stocked in 25 ft., 50 ft., and 100 ft. coils
  • Supplied double bagged
  • Documented lot traceable with identification on bags
  • Documented quality control
  • Complete validation package available upon request
  • Non-listed sizes, custom lengths, and special packaging available upon request
  • For pump applications, see APSPG Pump Grade Silicone Tubing
  • APST has a Master File with the U.S. Food and Drug Administration (#26598)

Brochure Advanta Sil APST Silicone Tubing

SPECIFICATIONS AND PROPERTIES

APST – UNREINFORCED PLATINUM CURED SILICONE TUBING

Screenshot from 2017-04-11 09-42-46
Sold by standard coil length only. Add length suffix code to product number when ordering—see the Coil Length Legend at right for length suffix codes. Example: 25 ft. of .030 in. I.D. x .160 in. O.D. tubing is product number APST-0030-0160P.

Working pressures are calculated from burst testing using a 3:1 safety factor. Application testing is recommended.

Coils and spools are supplied double bagged in heat-sealed polybags and bulk packed. Contact your AdvantaPure Sales Representative for other packaging options.

Notes Legend
*Limited stock availability; lead times and minimums may apply—call for details.
†Available in longer legths on spools—call for details.

NOTE: The data listed throughout this web site is meant only as a guide to aid in design, and is believed to be reliable; however, nothing stated shall constitute a guarantee or warranty for any application. Product field-testing should be performed to find the actual values for a specific application.

Coil Length Legend

P = 25 feet
L = 50 feet
K = 100 feet

Sold by standard coil length only. Add length suffix code to product number when ordering—see the Coil Length Legend at right for length suffix codes. Example: 25 ft. of .030 in. I.D. x .160 in. O.D. tubing is product number APST-0030-0160P.

Working pressures are calculated from burst testing using a 3:1 safety factor. Application testing is recommended.

Coils and spools are supplied double bagged in heat-sealed polybags and bulk packed. Contact your AdvantaPure Sales Representative for other packaging options.

Notes Legend
*Limited stock availability; lead times and minimums may apply—call for details.
†Available in longer legths on spools—call for details.
NOTE: The data listed throughout this web site is meant only as a guide to aid in design, and is believed to be reliable; however, nothing stated shall constitute a guarantee or warranty for any application. Product field-testing should be performed to find the actual values for a specific application.